Steam Sterilizer, Steam Autoclave, Horizontal Sterilizer manufacturer / supplier in China, offering 280L Horizontal Cylindrical Pressure Steam Sterilizer (microcomputer control) (MS-H280(D)), Stainless Steel Dog Cage (CG2806), Vet Video Colonoscope (Maxco 128V) and so on.

(/ )

Supplier Homepage Product Medical Surgery Devices Autoclave/Surgical Instruments 280L Horizontal Cylindrical Pressure Steam Sterilizer (microcomputer control) (MS-H280(D))

280L Horizontal Cylindrical Pressure Steam Sterilizer (microcomputer control) (MS-H280(D))

FOB Price: Get Latest Price
Min. Order: 1 Piece
Production Capacity: 5000PCS/Year
Transport Package: Carton
Payment Terms: T/T, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: MS-H280(D)
  • Type: Pressure Steam Sterilization Equipments
  • Medical Device Regulatory Type: Type 2
  • Sterilizing Chamber: 280L
  • Working Temperature: 134º C
  • Time of Sterilization: 0-99 Min
  • Trademark: SHINOVA
  • Origin: China
  • Theory: Autoclave
  • Certification: CE, ISO13485
  • Medical Devices Reg./Record No.: 2570313
  • Working Pressure: 0.22MPa
  • Adjustment of Temperature: 40º C - 134º C
  • Heat Average: ≤ ± 2º C
  • Specification: ISO, CE
  • HS Code: 84192000
Product Description
Horizontal cylindrical pressure steam sterilizer (microcomputer control)(MS-H150(D))
Model: MS-H150(D)
 
 Characteristics: 
1.Sterilizing course automatic sterilization controlled by computer, easy to operate.
2.With drying function, suitable dressing drying.
3.With over-temperature, over-pressure auto-protect device.
4.The door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027MPa.It can't be start on if the doesn't closed well.
5.The safety value will be open automatically when the inner pressure over 0.24MPa, and the steam be exhausting to the water tank.
6.The power will be cut-off automatically, cut-off the water and alarm when the machine lacking water.
7.The chamber of the sterilizer is made of stainless steel.
8.With printer.

Technical data:
Technical dataMS-H150(D)MS-H200(D)MS-H280(D)
Sterilizing chamber 
 volume
150L
φ440×1000mm
200L
φ515×1000mm
280L
φ600×1000mm
working pressure0.22 MPa
working  temperature134ºC
Adjustment of temperature40ºC - 134ºC
Time of sterilization0-99 min
Time of drying0-99 min
Heat average≤± 2ºC
Power9KW/380V 50Hz9KW/380V 50Hz12KW/380V 50Hz
Dimension1400×650×16001400×750×17001520×910×1900
Transport dimension1560×820×18201560×910×18801680×1080×2100
 G.W/N.W430/340 KG436/350 KG570/462 KG