Gold Member Since 2007
Audited Supplier
Shinova Medical Co., Ltd.

Chemistry Analyzer, Chemistry Analyzers, Automatic Chemistry Analyzer manufacturer / supplier in China, offering Veterinary Automatic Chemistry Analyzer (Chemo 200V), 5L Oxygen Concentrator (7F-5), 22L LCD Pre-Vacuum Sterilizer (PV-22G) and so on.

(/ )

Supplier Homepage Product Veterinary Laboratory Diagnostics Chemistry/Hematology Analyzer Veterinary Automatic Chemistry Analyzer (Chemo 200V)

Veterinary Automatic Chemistry Analyzer (Chemo 200V)

FOB Price: Get Latest Price
Min. Order: 1 Piece
Production Capacity: 5000PCS/Year
Transport Package: Carton
Payment Terms: T/T, Paypal, Western Union

Request a custom order and have something just for you!

Send Customized Request
Product Catalog
Shinova Veterinary Laboratory Diagnostics
29 Products
Content
Product Image
Product Name
FOB Price
Port
Payment Terms
Basic Info
  • Model NO.: Chemo 200V
  • Analytical Modes: End-Point, Two Point,Kinetic
  • Refrigerated Temperature: 2-8 °c
  • Specification: ISO, CE
  • HS Code: 90278090
  • Test: 200/H
  • Sample Volume: 2~100UL, with 0.1UL Increment
  • Trademark: Shinova
  • Origin: China
Product Description
Veterinary Automatic Chemistry Analyzer(Chemo 200V)
Model: Chemo 200v

Specifications:
· Assay methods: End Point, Kinetic, Fix time etc.
· Principle: Photoelectric colorimetry
· Light Source: Halogen lamp 12V/20W
· Photometry range: 0~3.2Abs
· Resolution: 0.0001Abs
· Wavelength: 340nm\405nm\450nm\492nm\510nm\546nm\578nm\630nm\700nm\800nm
· Throughput: 200 tests/hour
· Reagent tray: 60 reagent positions (include1detergent position, 1 dilution position)
· Sample tray: 71sample positions, standard, QC, STAT positions
· Reaction tray: 120 reaction cuvettes
· Sample volume: 2~100ul, with 0.1ul increment
· Reagent volume: R1: 10~500uL, R2: 10~500uL, with 0.5uL increment
· Minimum reaction volume: 150uL
· Maximum reaction time: 10 minutes
· Water Consumption: 5L/hour under working status
· Clean unit: 8-step auto-washing system with detergent
· Calibration: Calibration reset, select best test point by reaction curve, no need second calibration Line/non-line; Multi-standards assay
· Control rules: Westgard multi-rule, Cumulative sum check, Twin plot 3 level controls for each ifem, analyxing and printing QC analysis diagram
· Temperature control: Incubator 37± 0.1º C
· Power supply: AC 230(1± 10%)V, 50/60Hz, 500VA
· Ambient: Operating temperature: 10~30º C
Relative humidity: ≤ 85%
Atmospheric pressure: 86~106kPa

Features:
· 24 hour non-stop cooling system to ensure reagent at 2-8º C
· Durable ceramic syringes to ensure accuracy & precision
· High accurate optical system
· Collision protection in both vertical and horizontal directions, stop & alarm automatically once touching barrier, not affect former tests
· Automatic eligible cuvettes detection & selection
· Select best test point by reaction curve, create new factor automatically
· Support LIS interface

Accurate Sampling(Sample/Reagent) System:
· Collision protection
· Liquid level detection
· Internal and external probe washing
· Probe depth adjustment automatically

[High performance mixer design]
· Bsence of cross contamination
· Optimal homogenization in minimum time
· Mixing immediately after dispensing of sample and the second reagent

Stable Optical System:
· High accurate, close, static state optical system
· Spot photometry with high speed digital transmission system
· Durable cuvettes
· 8-step auto-washing system with detergent and deion-water to ensure cuvettes clean and decrease cross contamination
· 120 reaction cuvettes located in a constant temperature incubator
· Low consumption, open reagent design

Multi-function sample/reagent tray:
· 60 reagent positions, support 25mL, 50 mL reagent bottle type.
· 45 sample positions including routine, stat, control and standard
· Various primary tubes and special cups can be used
· Up to 20 virtual sample tray can be programmed
· 24 hours nonstop cooling system with peltier element

Dynamic and real time display of running status:
· Running status of reagent tray, sample tray and reaction tray
· Real time monitoring of reagent residual volume
· Intelligent carry over setting to adjust test sequence, STAT test priority
· Probe depth adjustment automatically
· Real time monitoring of reaction curve
· Real time diagnosis of system working status
Product Groups